Zuhause> Produkt-Liste> Industrial UPS> Dreiphasen industrielle niedrige Online -Ups industriellem Frequenz
Dreiphasen industrielle niedrige Online -Ups industriellem Frequenz
Dreiphasen industrielle niedrige Online -Ups industriellem Frequenz
Dreiphasen industrielle niedrige Online -Ups industriellem Frequenz
Dreiphasen industrielle niedrige Online -Ups industriellem Frequenz
Dreiphasen industrielle niedrige Online -Ups industriellem Frequenz
Dreiphasen industrielle niedrige Online -Ups industriellem Frequenz
Dreiphasen industrielle niedrige Online -Ups industriellem Frequenz
Dreiphasen industrielle niedrige Online -Ups industriellem Frequenz

Dreiphasen industrielle niedrige Online -Ups industriellem Frequenz

Holen Sie sich aktuelle Preis
Zahlungsart:L/C,T/T,D/P,D/A,Paypal
Incoterm:FOB,Express Delivery,CFR,CIF,DAF,DES,EXW,FAS,FCA,CPT,CIP,DEQ,DDP,DDU
Transport:Ocean,Land,Air,Express
Hafen:CNYTN ,CNSHK
The output voltage:
Produkteigenschaften

ModellUT33 Series Power Frequency Online UPS

MarkeUnitronic Power

Garantiezeit3 Monate-1 Jahr, andere, 3 Jahre

HerkunftsortChina

PhaseDrei Phasen

SchutzBlitz, Kurzschluss, Überspannung, Überstrom, Unausgeglichene Lasten

Gewichtandere

Arten VonOnline

GeltungsbereichCOMPUTER, Sicherheit / Überwachung / Alarm, Militär, MEDIZINISCH, INSTRUMENTIERUNG, Vernetzung, Telekommunikation

Capacity10KVA/15KVA/20KVA/30KVA/40KVA/60KVA/80KVA/100KVA/120KVA /160KVA/200KVA/250KVA/300KVA/400KVA/500KVA/600KVA/800KVA

Verpackung & Lieferung
Verkaufseinheiten : Piece/Pieces
Pakettyp : Kartonverpackung
Bildbeispiel :
Herunterladen :
Produktbeschreibung

UT33 series 10KVA/10KW, 15KVA/15KW, 20KVA/20KW, 30KVA/30KW, 40KVA/40KW, 60KVA/60KW, 80KVA/80KW, 100KVA/100KW, 120KVA/120KW,160KVA/160KW,200KVA/200KW,250KVA/250KW, 300KVA/300 kW, 400 kVA/400 kW, 500KVA/500 kW, 600 kVA/600 kW, 800kVA/800 kW UPS sind ein transformatorbasiertes UPS, das üblicherweise in der industriellen Stromversorgung verwendet wird. Diese industrielle UPS -Serie ist eine niedrige UPS mit flexibler Weaver -Technologie und intelligenter Batteriemanagementfunktion. Die Schutzfunktion ist vollständig und mit Schall und leichtem Alarm ausgestattet. Häufig in Rechenzentren, Netzwerkräumen, intelligenten Präzisionsgeräten, Finanzen, Telekommunikation, Versicherung, Transport, Besteuerung, Militär, Sicherheit, Energie, Bildung, Regierung, Fertigung und anderen Branchen verwendet.





◆ Anwendung

D ATA -Zentrum, Netzwerk Computerraum, intelligente Präzisionsausrüstung , Finanz-, Telekommunikations-, Versicherungs-, Transport-, Steuern, Militär-, Sicherheit, Energie, Bildung, Regierung, Fertigung und andere Branchen usw.

◆ Funktionen

Hoher zuverlässiger statischer Schalter

● Selbstdiagnose und Selbstschutz

● wiederaufladbares Batterie -intelligentes Management

Hu -Man-Machine-Dialog mit der Fernüberwachung und der Netzwerkverwaltung

● Starke englische Anzeigeschnittstelle

● Doppeltransformation ist Online-Design

● Flexible Webertechnologie

● System mit hoher Effizienz

O UTPUT -Transformator

● mit optionalem 12 -Impulsgleichrichter

Ermöglichen _

● Intelligente Batterieverwaltungsfunktion

● Um die Funktion zu schützen, ist alles fertig

● Geräusch- und Lichtalarm

● eine Vielzahl von Spannungsausgang

● farb optional



Model

UT33010

UT33015

UT33020

UT33030

UT33040

UT33060

UT33080

UT33100

UT33120

Capacity

10kVA

15kVA

20kVA

30kVA

40kVA

60kVA

80kVA

100kVA

120kVA

Input

Phase

3-phase+N+G

Rated Voltage

440/460/480Vac

Input Voltage Range

285-528Vac

Rated Frequency

50/60Hz

Input Frequency Range

50H±10%, 60Hz±10%

THDi

10%

Soft Start

1-100%, 5 seconds

Bypass

Phase

3-phase+N+G

Voltage Range

440/460/480Vac ±10%

Frequency Range

50/60H±10%

Output

Rated Voltage

440/460/480Vac

Voltage Regulation

±1% for balance load; ±3% for unbalance load

Rated Frequency

50/60Hz

Frequency Precision

50/60Hz±0.05%Battery mode)

Outout PF

0.9

THDu

2% (linear load); 4% (non-linear load)

Crest Factor

3:1

Dynamic Voltage Transient

5% (from 0 to 100% load)

Transient Recovery Time

10ms (±5%)

Inverter Overload

125% load for 10 mins; 150% load for 1min

Battery

Voltage

360Vdc

Battery Type

Sealed maintenance-free lead-acid battery

Charging Voltage

Float charging: 405Vdc; boost charging: 435Vdc

Charging Current

1-50A, settable according the battery capacity

System

Efficiency

91%

Protection Function

Output short circuit protection; current-limiting protection

Transfer Time

Normal mode to battery mode, 0ms

Display

LCD+LED+Keyboard

IP Class

IP20

Communication Interface

RS232, RS485(optional), SNMP card (optional)

Temperature

Operation: 0-40 ℃; storage: -25-55 ℃

Relative Humidity

0-95%, no-condensing

Altitude

1500. Within 1500 to 4000m, power capacity decreases by 1% per 100m increasing in altitude

Noise (1-meter away)

65dB

Physical

Weight (kg)

200

250

340

400

480

650

900

1200

1300

Dimension (W*D*H)mm

725*450*1135

855*450*1235

715*855*1500

1100*900*1700



Model

UT33160

UT33200

UT33250

UT33300

UT33400

UT33500

UT33600

UT33800

Capacity

160kVA

200kVA

250kVA

300kVA

400kVA

500kVA

600kVA

800kVA

Input

Phase

3-phase+N+G

3-phase+G

Rated Voltage

440/460/480Vac

Input Voltage Range

285-528Vac

Rated Frequency

50/60Hz

Input Frequency Range

50H±10%, 60Hz±10%

THDi

10%

Soft Start

1-100%, 5 seconds

5-600 seconds, settable

Bypass

Phase

3-phase+N+G

Voltage Range

440/460/480Vac ±10%

Frequency Range

50/60H±10%

Output

Rated Voltage

440/460/480Vac

Voltage Regulation

±1% for balance load; ±3% for unbalance load

Rated Frequency

50/60Hz

Frequency Precision

50/60Hz±0.05%Battery mode)

Outout PF

0.9

THDu

2% (linear load); 4% (non-linear load)

1% (linear load); 3% (non-linear load)

Crest Factor

3:1

Dynamic Voltage Transient

5% (from 0 to 100% load)

Transient Recovery Time

10ms (±5%)

Inverter Overload

125% load for 10 mins; 150% load for 1min

100%, continue; 125% load for 10 mins; 150% load for 1min

Battery

Voltage

360Vdc

480Vdc, default (456Vdc, 504Vdc, settable)

Battery Type

Sealed maintenance-free lead-acid battery

Charging Voltage

Float charging: 405Vdc; boost charging: 435Vdc

Float charging: 540Vdc; boost charging: 580Vdc

Charging Current

1-50A, settable according to the battery capacity

System

Efficiency

91%

94%

Protection Function

Output short circuit protection; current-limiting protection

Transfer Time

Normal mode to battery mode, 0ms

Display

LCD+LED+Keyboard

IP Class

IP20

Communication Interface

RS232, RS485(optional), SNMP card (optional)

Temperature

Operation: 0-40 ℃; storage: -25-55 ℃

Relative Humidity

0-95%, no-condensing

Altitude

1500. Within 1500 to 4000m, power capacity decreases by 1% per 100m increasing in altitude

Noise (1-meter away)

65dB

71dB

72dB

74dB

Physical

Weight (kg)

1480

2000

2050

2100

2500

3000

3500

4100

Dimension (W*D*H)mm

1200*1500*1800

1300*1800*1800

2615*855*1900

2865*950*1900

3800*950*1900


Zuhause> Produkt-Liste> Industrial UPS> Dreiphasen industrielle niedrige Online -Ups industriellem Frequenz
Anfrage versenden
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

senden